Boiler rooms gas detection systems

Regardless of its size, a boiler room presents potential significant risks. Actually, a gas leak could have severe consequences for people and goods. Installing a boiler room gas detection system is an efficient and simple way to reduce these risks.

Boiler rooms gas detection systems

Most of gas boiler rooms run without permanent monitoring and a gas leak could stay unnoticed. Boiler rooms gas detection controllers mainly remove these risks triggering valve actuators. In presence of any flammable gas detection (liquefied petroleum gas or natural gas), a controller will shut down gas supply with a gas solenoid valve installed outside the boiler room.

Boiler rooms standards and regulations

Bigger gas detection systems for boiler rooms are regulated under specific laws but common sense implies same boiler room safety regulations for smaller boiler rooms. For gases that are lighter than air – such as methane – the detector will be placed above the burner. For gases heavier than air – such as butane or propane – the detector will be placed below the burner.
 
An additional detector shall be placed at an upper point in boiler rooms with high ceilings (beyond 3 meters). It can also be placed in the extraction system to have twin detection (burner and ceiling) regardless of the number of burners (furnace).

Boiler rooms gas detection: different alarm thresholds

A gas detection controller for boiler heating systems manages every gas detector and features relays for alarm signals and valves actuators:

  • Level 1: 10 or 15 % of the LEL (lower explosive limit), visual and audible signal with alarm report for fast on-site intervention
  • Level 2: Between 20 and 40 % of the LEL, gas supply shutdown through a manual reset boiler gas valve (human action to reactivate the boiler room)
  • Level 3: Only for biggest gas boiler heating systems. Starting at 60% of the LEL, direct action on the main LV board and complete shutdown of any power supply (except the gas detection controller)

Our gas equipment for boiler rooms:

The main - and most efficient - action in case of gas presence is the gas supply shutdown through a manual or automatic reset gas safety valve. As this solenoid valve is controlled by a gas detection controller, it will close through a tension interruption in case of an alarm…

SIL 2 approved ATEX gas detector to detect the combustible gases (IR or catalytic), CO2 (IR), toxic gases (electrochemical), solvents or freons (semiconductor) and asphyxiating gases (oxygen deficiency).

  • Fixed gas detector OLCT100
  • Detection of hydrocarbons, solvents, toxic gases, freons, VOC, CO2
  • Housing made of aluminium with epoxy paint (optional 316L Stainless Steel version)
  • Outputs: OLC100: Wheatstone bridge – OLCT100: 4-20 mA linear
  • Power supply: 15.5 to 32 VDC
  • ATEX & SIL 2 approved for catalytic and infrared versions
  • Additional information
Request a quote

Fixed gas detector – OLCT100

SIL 2 approved ATEX gas detector to detect the combustible gases (IR or catalytic), CO2 (IR), toxic gases (electrochemical), solvents or freons (semiconductor) and asphyxiating gases (oxygen deficiency).

Fixed gas detector OLCT100
  • Detection of hydrocarbons, solvents, toxic gases, freons, VOC, CO2
  • Housing made of aluminium with epoxy paint (optional 316L Stainless Steel version)
  • Outputs: OLC100: Wheatstone bridge – OLCT100: 4-20 mA linear
  • Power supply: 15.5 to 32 VDC
  • ATEX & SIL 2 approved for catalytic and infrared versions
Additional information

Thanks to the wide variety of sensor technologies that can be used with this monitor, the OLCT100 fixed gas detector can detect a large range of gases. The combustible gases can be detected with a catalytic or infrared sensor, toxic gases with an electrochemical sensor, freons with a semiconductor sensor and carbon dioxide with an infrared sensor.

Two outputs types are available for this fixed gas detector range. The first one is the 4-20 mA analog output. It can be used to detect combustible, toxic and asphyxiating gases but also solvents, freons or carbon dioxide. The second output version is a Wheatstone bridge for the detection of combustible gases (0-100% LEL only).

Many accessories are available for the OLCT100 gas detector to improve sensor response time or to get optimal implementation.

The OLC/OLCT100 range is available under 5 versions:

  • OLC100 : Wheatstone bridge output detector to detect the combustible gases (0-100% LEL only)
  • OLCT 100 XP: Explosion-proof version equipped with a catalytic, electrochemical or semiconductor sensor to detect the combustible or toxic gases or oxygen.
  • OLCT 100 IS: Extremely reliable version to detect toxic gases or oxygen.
  • OLCT 100 XP IR: Explosion-proof version equipped with an infrared sensor to detect the combustible gases or CO2
  • OLCT 100 XP HT: High temperature explosion-proof version to detect combustible gases up to 200 °C
Request a quote
Learn more

Digital gas detection controller MX32N

The MX32N digital gas controller is a digital controller and alert management device. As it can be linked to 8 detectors, the MX32N allows monitoring of hazardous gases (combustible, toxic or asphyxiating) in the most demanding environments.

  • Oldham digital gas detection controller MX32N fro fixed systems
  • Two-in-one detector: digital and analog.
  • 1 or 2 independent channels.
  • Continuous monitoring of hazardous gas.
  • 5 alarm thresholds (sound and visual alarms).
  • IP66 protection.

Request a quote

Digital gas detection controller MX32N

The MX32N digital gas controller is a digital controller and alert management device. As it can be linked to 8 detectors, the MX32N allows monitoring of hazardous gases (combustible, toxic or asphyxiating) in the most demanding environments.

Oldham digital gas detection controller MX32N fro fixed systems
  • Two-in-one detector: digital and analog.
  • 1 or 2 independent channels.
  • Continuous monitoring of hazardous gas.
  • 5 alarm thresholds (sound and visual alarms).
  • IP66 protection.

Request a quote
Learn more

Multichannel gas detection controller – up to 43 channels – MX43

Gas detection controller with 4 or 8 analog and/or digital channels (up to 32 detectors allocated to 8 channels) for monitoring gases in the atmosphere.

  • Fixed gas detection controller MX43
  • Many upgrade opportunities (additional cards)
  • 5 alarm levels
  • 5 fully programmable alarm relays + fault
  • Integrated sounder and visual signal
  • Communication: RS 485, proprietary protocol, 9,600 Baud
Request a quote

Multichannel gas detection controller – up to 43 channels – MX43

Gas detection controller with 4 or 8 analog and/or digital channels (up to 32 detectors allocated to 8 channels) for monitoring gases in the atmosphere.

Fixed gas detection controller MX43
  • Many upgrade opportunities (additional cards)
  • 5 alarm levels
  • 5 fully programmable alarm relays + fault
  • Integrated sounder and visual signal
  • Communication: RS 485, proprietary protocol, 9,600 Baud
Request a quote
Learn more

Manual reset gas solenoid valve – ELK600

Manual reset safety solenoid valve for 500 mbar maximal pressure

  • Gas solenoid valve ELK600
  • Connection: thread F/F gas (3/8” à 2”) – flanged PN16 UNI2223 (DN65 to DN150)
  • Power supply: 230V (upon request: 110V – 50/60 Hz / 12-24 V – AC/DC)
  • Opening/closure time < 1 second
  • operating pressure: 500 mbar
  • End of course upon request
Request a quote

Manual reset gas solenoid valve – ELK600

Manual reset safety solenoid valve for 500 mbar maximal pressure

Gas solenoid valve ELK600
  • Connection: thread F/F gas (3/8” à 2”) – flanged PN16 UNI2223 (DN65 to DN150)
  • Power supply: 230V (upon request: 110V – 50/60 Hz / 12-24 V – AC/DC)
  • Opening/closure time < 1 second
  • operating pressure: 500 mbar
  • End of course upon request